  1. Principle:
    Different viscosity of the aqueous solution of sodium alginate on the pH glass electrode and calomel electrode produce different dc emfs, indicating its pH value through the amplifier.
  2. Instruments:
    Acidity meter: accuracy of 0.01 pH unit.
  3. Reagents:
    Experimental water Should accord with the requirement of tertiary water in GB6682.
  4. Measuring steps:
    ㈠.Preparation of 1% sodium alginate solution: according to take a sample of 1 g (called a quasi to 0.01 g), add 99 ml of distilled water, stirring to dissolve into a homogeneous solution, the solution concentration was 1%.
    ㈡.The determination of pH :According to the provisions of the ph meter to use ,Acidity meter calibration first, Then with a capacity of 100 ml beaker containing 1% sodium alginate solution 50 ml , The electrodes immersed in the solution,Start the acidity meter, Determination ofsolution pH .Shaking when measuring solution, when the pointer or display value stable reading.
  5. The results calculated :Each sodium alginate sample take for determination of two parallel samples,Take the arithmetic mean value as result.
  6. Repeatability :Two parallel samples results difference (absolute value) must not exceed 0.10,
    Otherwise renewedly prepared solutio .